Composite Suspension Insulators are electrical components designed specifically for suspension applications in high-voltage electrical systems. They consist of a core material made of insulating silicone rubber or other polymer materials, surrounded by a weather-resistant, flexible outer shell. The suspension insulators are suspended from overhead power lines and provide electrical insulation between the conductor and the support structure.
Specifications
Composite Suspension Insulator
Composite Suspension Insulator voltage class:
11kV, 12kV,15kV,24kV, 33kV, 36kV,69kV, 110kV, 132kV, 138kV,169kV, 220kV, 245kV, 330kV, 400kV, 420kV, 500kV 750kV
Composite Suspension Insulator Specific Mechanical load:
40kN,50kN, 70kN, 100kN, 110kN, 120kN, 160kN, 210kN
Composite Suspension Insulator Standard of execution
IEC61109, IEC61952, IECC29.11
Composite Suspension Insulator Mark of gold instrument:
NO. |
Rated voltage
(kV)
|
Rated mechanical tensile load
(KN)
|
The height of the structure (mm) | Minimum arc distance(mm) | The minimum nominal creepage distance(mm) | The diameter of umbrella(mm) | Lightning impulse withstand voltage (peak)(kV) | Power frequency withstand voltage 1min(kV) |
1 | 11 | 70 | 325±5 | 220±5 | 430 | 125/110 | 110 | 42 |
NO. |
Rated voltage
(kV)
|
Rated mechanical tensile load
(KN)
|
The height of the structure (mm) | Minimum arc distance(mm) | The minimum nominal creepage distance(mm) | The diameter of umbrella(mm) | Lightning impulse withstand voltage (peak)(kV) | Power frequency withstand voltage 1min(kV) |
2 | 12 | 70 | 350±10 | 226±5 | 475 | 99±1 | 125 | 50 |
NO. |
Rated voltage
(kV)
|
Rated mechanical tensile load
(KN)
|
The height of the structure (mm) | Minimum arc distance(mm) | The minimum nominal creepage distance(mm) | The diameter of umbrella(mm) | Lightning impulse withstand voltage (peak)(kV) | Power frequency withstand voltage 1min(kV) |
3 | 24 | 70 | 430±15 | 314±5 | 690 | 99±1 | 150 | 75 |
NO. |
Rated voltage
(kV)
|
Rated mechanical tensile load
(KN)
|
The height of the structure (mm) | Minimum arc distance(mm) | The minimum nominal creepage distance(mm) | The diameter of umbrella(mm) | Lightning impulse withstand voltage (peak)(kV) | Power frequency withstand voltage 1min(kV) |
4 | 33 | 70 | 530±15 | 400±5 | 925 | 99±1 | 150 | 75 |
NO. |
Rated voltage
(kV)
|
Rated mechanical tensile load
(KN)
|
The height of the structure (mm) | Minimum arc distance(mm) | The minimum nominal creepage distance(mm) | The diameter of umbrella(mm) | Lightning impulse withstand voltage (peak)(kV) | Power frequency withstand voltage 1min(kV) |
5 | 36 | 70 | 590±15 | 475±5 | 1200 | 98/69 | 210 | 95 |
NO. |
Rated voltage
(kV)
|
Rated mechanical tensile load
(KN)
|
The height of the structure (mm) | Minimum arc distance(mm) | The minimum nominal creepage distance(mm) | The diameter of umbrella(mm) | Lightning impulse withstand voltage (peak)(kV) | Power frequency withstand voltage 1min(kV) |
6 | 36 | 70 | 570±15 | 448±5 | 1040 | 99±1 | 170 | 90 |
NO. |
Rated voltage
(kV)
|
Rated mechanical tensile load
(KN)
|
The height of the structure (mm) | Minimum arc distance(mm) | The minimum nominal creepage distance(mm) | The diameter of umbrella(mm) | Lightning impulse withstand voltage (peak)(kV) | Power frequency withstand voltage 1min(kV) |
7 | 33 | 25 | 700±15 | 505±5 | 1350 | 140/110 | 230 | 95 |
NO. |
Rated voltage
(kV)
|
Rated mechanical tensile load
(KN)
|
The height of the structure (mm) | Minimum arc distance(mm) | The minimum nominal creepage distance(mm) | The diameter of umbrella(mm) | Lightning impulse withstand voltage (peak)(kV) | Power frequency withstand voltage 1min(kV) |
8 | 36 | 100 | 645±15 | 505±5 | 1350 | 140/110 | 230 | 95 |
NO. |
Rated voltage
(kV)
|
Rated mechanical tensile load
(KN)
|
The height of the structure (mm) | Minimum arc distance(mm) | The minimum nominal creepage distance(mm) | The diameter of umbrella(mm) | Lightning impulse withstand voltage (peak)(kV) | Power frequency withstand voltage 1min(kV) |
9 | 33 | 40 | 330±15 | 270±5 | 730 | 131/90 | 170 | 75 |
NO. |
Rated voltage
(kV)
|
Rated mechanical tensile load
(KN)
|
The height of the structure (mm) | Minimum arc distance(mm) | The minimum nominal creepage distance(mm) | The diameter of umbrella(mm) | Lightning impulse withstand voltage (peak)(kV) | Power frequency withstand voltage 1min(kV) |
10 | 66 | 70 | 877±15 | 730±5 | 2150 | 140/108 | 420 | 120 |
NO. |
Rated voltage
(kV)
|
Rated mechanical tensile load
(KN)
|
The height of the structure (mm) | Minimum arc distance(mm) | The minimum nominal creepage distance(mm) | The diameter of umbrella(mm) | Lightning impulse withstand voltage (peak)(kV) | Power frequency withstand voltage 1min(kV) |
11 | 132 | 70 | 1350±15 | 1230±5 | 3850 | 140/108 | 820 | 240 |
NO. |
Rated voltage
(kV)
|
Rated mechanical tensile load
(KN)
|
The height of the structure (mm) | Minimum arc distance(mm) | The minimum nominal creepage distance(mm) | The diameter of umbrella(mm) | Lightning impulse withstand voltage (peak)(kV) | Power frequency withstand voltage 1min(kV) |
12 | 220 | 120 | 2316±15 | 2138±5 | 6930 | 140/108 | 1360 | 400 |